FUSIBLE LINK
Inline Thermal Check Valve
MODEL FL-200
REFERENCE DATA:
FL-200 Series Assembly Drawing No. A88-60200-00.
INSTALLATION:
1. Clean the piping of all foreign material including chips, welding scale, oil, grease and dirt before installing the thermal
trip valve.
2. In placing thread sealant on pipe ends prior to engagement, ensure that excess material is removed and not allowed
to enter the thermal trip valve upon startup.
3. Flow Direction: Install so the ow direction matches the ow arrow on the body of the thermal trip valve.
PRINCIPLE OF OPERATION:
1. When the valve is installed it is open.
2. This valve will stay open until it is actuated by the fusible link.
3. This will cause the valve to close.
MAINTENANCE:
1. All valves are leak tested at the factory at 200 PSIG and should be externally leak tight after installation. If after pro-
longed ser vice the valve should leak externally, it is recommended that the valve be replaced or sent to the factory
for rebuilding.
IOM-FL
11-13
MAINTENANCE & ASSEMBLY INSTRUCTIONS
Vedere la pagina 0
1 2 3 4 5

Sommario

Pagina 1 - FUSIBLE LINK

FUSIBLE LINKInline Thermal Check ValveMODEL FL-200REFERENCE DATA: FL-200 Series Assembly Drawing No. A88-60200-00.INSTALLATION:1. Clean the piping o

Pagina 2 - FL-200 SERIES

IOM-FL2NOTES:1. Maximum pressure rating 130 psig (896 kPa) WOG.2. No changes shall be made to parts, material or manufacturing process without prior

Pagina 3

IOM-FL3FUSIBLE LINKBarstock Thermal Shutoff ValvesMODEL FL-800 S and VREFERENCE DATA: FL-800 Series Assembly Drawing No. A66-60800-00, A66-60800-01,

Pagina 4 - VALVES FL-800 SERIES

IOM-FL4View 1Type S (Standard)View 2BARSTOCK THERMAL SHUT-OFFVALVES FL-800 SERIESType V (Vented)View 3Fusible LinkFusible LinkNOTES:1. Maximum pressu

Pagina 5

Cashco, Inc.P.O. Box 6 Ellsworth, KS 67439-0006PH (785) 472-4461Fax. # (785) 472-3539www.cashco.comemail: [email protected] in U.S.A. FL-IOMC